Sign In | Join Free | My udpf.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Patient Monitor Parts >

115VA PHiliph Goldway UT4000F Patient Monitor Power Switch Key Board With Fuses Button

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

115VA PHiliph Goldway UT4000F Patient Monitor Power Switch Key Board With Fuses Button

Brand Name : Goldway

Model Number : UT4000F

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

Product name : Goldway

Type : UT4000F

Application : Patient Monitor

Warranty : 90days

Product Condition : In Good Working Order

KeyWords : patient monitor power supply board

Minimum purchase contract : 1pcs

Applications Scenes : Hospital, Clinic, Hospital room, ICU,etc

Goodness : Original,Professional technical team

Sale protection : If there are any problems caused by us, we will be free for you to repair or returned

Management Aims : Advanced technology, high-quality products, attentive service

Inventory : Sufficient inventory

Method of transport : Express delivery

Power Supply : 110-230 VAC, 50/60Hz

Input Power : ≤115VA

Fuses : Two fuse sockets in the rear panel indicated by symbol of fuse, T2.0AL, 250V ~

Contact Now

PHiliphh Goldway UT4000F Patient Monitor Power Switch Key Board with Fuses Button

Brief Introduction

The PHiliphh Goldway UT4000F Patient Monitor Power Switch Key Board with Button is a component of the PHiliphh Goldway UT4000F Patient Monitor. It is a keyboard with a power switch button that is used to control the power functions of the monitor.

► Functional

Locate the Power Switch Key Board on the monitor. It is usually located on the front or side of the device.

Make sure the monitor is properly connected to a power source, such as a wall outlet or battery.

Insert the key into the Power Switch Key Board. The key is usually provided with the monitor and may have a unique shape or design.

Turn the key clockwise or counterclockwise to the "On" position to power on the monitor. The monitor should start displaying information and functioning.

If you need to power off the monitor, turn the key back to the "Off" position.

The Fuses Button on the Power Switch Key Board is designed for fuse replacement. If a fuse blows or requires replacement, you can carefully press the Fuses Button to open the panel where the fuses are located.

Replace the blown or faulty fuse with a new one of the same type and rating. Make sure to use the appropriate replacement fuse to avoid any electrical issues or damage.

Close the fuse panel by pushing it back into place until it clicks or locks securely.

How To Use

Locate the power switch key on the keyboard. It is usually labeled with a power symbol (a circle with a vertical line in the center).

Ensure that the patient monitor is properly connected to a power source and turned on.

Press and hold the power switch key for a few seconds until the monitor powers on. You may see a startup screen or the monitor display turning on.

If the monitor doesn't turn on, check the fuses button on the keyboard. Locate the fuses button, which is generally labeled with a fuse symbol or the word "FUSES."

Using a small tool like a screwdriver or a coin, turn the fuses button counterclockwise to open the fuse compartment.

Inspect the fuses inside the compartment to see if any are blown. If you notice a blown fuse, carefully remove it and replace it with a new one of the same rating.

Once the fuse is replaced, turn the fuses button clockwise to close the fuse compartment.

Attempt to power on the patient monitor again by pressing and holding the power switch key on the keyboard.

If the monitor still doesn't turn on, it may indicate a more significant issue. In such cases, it is recommended to consult the user manual or contact the manufacturer's customer support for further assistance.

Specification

Power Supply 110-230 VAC, 50/60Hz
Input Power ≤115VA
SpO2 Measure Range 50 ~ 100%
SpO 2 Averaging 8 second average
Repeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutes
Fuses Two fuse sockets in the rear panel indicated by symbol of fuse, T2.0AL, 250V ~

115VA PHiliph Goldway UT4000F Patient Monitor Power Switch Key Board With Fuses Button

If you have any questions about PHiliphh Goldway UT4000F Patient Monitor Power Switch Key Board with Fuses Button, please feel free to contact us at any time, we are glad to answer them. Thank you for your time!


Product Tags:

Patient Monitor Power Switch Key Board

      

UT4000F Power Switch Key Board

      
Best 115VA PHiliph Goldway UT4000F Patient Monitor Power Switch Key Board With Fuses Button wholesale

115VA PHiliph Goldway UT4000F Patient Monitor Power Switch Key Board With Fuses Button Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)